Security Systems Comparision Chart

 
NAPCO GEMINI PRODUCTS
NAPCO MAGNUM
 

GEM-P800/P801

GEM-P816

GEM-P1632

GEM-P3200

GEM-P9600

MA3000LKDL
ZONES ON BOARD
8
8
8
8
8
8
MAX # ZONES
16
16
32
32/48
96
96
ZONE EXPANSION
(*NOTE: Each RP1CAe2/RP3000LCD Keypad adds 4 Built-in Zones)
--
2xGEM-EZM4/8
1xGEM-EZM8
*
6xGEM-EZM4/8
3xGEM-EZM8
*
3xGEM-EZM8
11xGEM-EZM8

11xEZM3008
*
# OF FIRE ZONES; 2 WIRE FIRE
1 2/3-Wire
Up to 16; 2 2-Wire
Up to 32; 2 2-Wire
Up to 32; 2 2-Wire
Up to 96; With up to 8 2-Wire Fire
Up to 96; With up to 8 2-Wire Fire
KEYPADS SUPPORTED
4(total) GEM-RP8
LCD keypad on GEM-P801
7(total) GEM-RP1CAe2
GEM-RP2ASe2
GEM-RP3DGTL
7(total) GEM-RP1CAe2
GEM-RP2ASe2
GEM-RP3DGTL
7(total) GEM-RP1CAe2
GEM-RP2ASe2
GEM-RP3DGTL
15(total) GEM-RP1CAe2
GEM-RP2ASe2
GEM-RP3DGTL
15(total) RP3000LCD or CF3000LCD Fire Model
EVENT LOG
50
256
400
800
800
800
# of AREAS
1
1
2
2
8
8
# of OUTPUTS
2
3
3, Up to 11
(using RB3008 Relay Modules)
3, Up to 27
(using RB3008 Relay Modules)
3, Up to 99
(using RB3008 Relay Modules)
3, Up to 67
(using RB3008 Relay Modules)
# of WIRELESS RECEIVERS SUPPORTED
2 (GEM-RECVXP8 only)
2 (GEM-RECVXP8 -16 or -96)
2 (GEM-RECVXP8 -16 or -96)
2 (GEM-RECVXP8 -16 or -96)
2 (GEM-RECVXP8 -16 or -96)
--
# WIRELESS POINTS
12
16
32
48
96
--
# WIRELESS KEYFOBS (GEM-KEYF)
4
8
8
8
16
--
AUTO ARM
--
YES
YES
YES
YES
--
OPEN/CLOSE LOGGING
--
YES
YES
YES
YES
YES
AUTO DISARM
--
--
--
YES
YES
YES
SCHEDULES
--
--
--
255
255
YES
LINE CUT DETECT
YES
YES
YES
YES
YES
YES
BELL SUPERVISION
YES
YES
YES
YES
YES
YES
COMMUNICATION FORMATS
Contact ID
Contact ID, SIA
Contact ID, SIA
Contact ID, SIA
Contact ID, SIA
Contact ID, SIA
PAGER FORMAT
YES
YES
YES
YES
YES
YES
RS232 OUTPUT OPTION FOR AUTOMATION INTEGRATION
--
--
--
--
YES
--
X-10 CAPABLE (LIGHTING,HEATING CONTROL)
--
--
8 Device, 16 Events
Yes - 24
Yes -64
Yes - 64
INPUT POWER
16.5 VAC
16.5 VAC
16.5 VAC
16.5 VAC
16.5 VAC
16.5 VAC
MAX. STANDBY CURRENT
2 AMPS
2 AMPS
2 AMPS
2 AMPS
2 AMPS
2 AMPS